<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>Technical Reports</title>
<link>http://hdl.handle.net/1969.1/1657</link>
<description>Technical Reports from the Energy Systems Laboratory</description>
<pubDate>Fri, 24 May 2013 15:45:14 GMT</pubDate>
<dc:date>2013-05-24T15:45:14Z</dc:date>
<item>
<title>Procedure for Packing Weather Files for DOE-2e</title>
<link>http://hdl.handle.net/1969.1/148726</link>
<description>Procedure for Packing Weather Files for DOE-2e
</description>
<pubDate>Wed, 01 Sep 2010 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://hdl.handle.net/1969.1/148726</guid>
<dc:date>2010-09-01T00:00:00Z</dc:date>
</item>
<item>
<title>Description and comparison of the results of the proposed house: habitat for humnaity at frazier court, Dallas, Texas, with the 2004 IECC standard reference house</title>
<link>http://hdl.handle.net/1969.1/148725</link>
<description>Description and comparison of the results of the proposed house: habitat for humnaity at frazier court, Dallas, Texas, with the 2004 IECC standard reference house
The Energy Systems Laboratory was requested to calculate the emissions reductions associated&#13;
with the Habitat for Humanity Housing Project at Frazier Court, Dallas Texas. This report presents the&#13;
results of the required analysis, a set of houses was compared to a corresponding standard reference house&#13;
as described in the 2004 International Energy Conservation Code (2004 IECC). The energy consumption&#13;
calculations were carried out using DOE-2.1e input file RES3ST.inp (Version 4.01.07) and DDP&#13;
(Version: 1.7.03). Based on this comparison, the % above/below code for the proposed house was&#13;
determined. The resultant emissions calculations were carried out using eCALC software (ESL, 2006).&#13;
This report also contains detailed information about the description of the proposed house in terms of its&#13;
building parameters, resultant energy consumption and emission reductions. Calculations are carried out&#13;
using TMY2 weather file for Tarrant County, TX which is in climate zone 3 of the IECC 2004 climate&#13;
zone categories. For the 1285 sq. ft. houses, the energy consumption of the Habitat for Humanity houses&#13;
is in the range of 10.3% - 11.7% above code and for the 843 sq. ft. houses, the energy consumption is in&#13;
the range of 20.9% - 21.4% below code. The HERS ratings calculated by IC3 is in the range of 71.7–&#13;
74.2 for the 1285 sq. ft. houses and in the range of 79.4 – 80.6 for the 843 sq. ft. houses.
</description>
<pubDate>Wed, 01 Sep 2010 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://hdl.handle.net/1969.1/148725</guid>
<dc:date>2010-09-01T00:00:00Z</dc:date>
</item>
<item>
<title>Validation fo the International Code Compliant Calculator (IC3) v3. 10.3 Using the RESNET Verification Procedures (No. 07-003)</title>
<link>http://hdl.handle.net/1969.1/128951</link>
<description>Validation fo the International Code Compliant Calculator (IC3) v3. 10.3 Using the RESNET Verification Procedures (No. 07-003)
</description>
<pubDate>Thu, 01 Dec 2011 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://hdl.handle.net/1969.1/128951</guid>
<dc:date>2011-12-01T00:00:00Z</dc:date>
</item>
<item>
<title>Cost-Effective Energy Efficiency Measures for Above Code(ASHRAE 90.1-2001 and 2007) Small Restaurant Buildings in the City of Arlington</title>
<link>http://hdl.handle.net/1969.1/128950</link>
<description>Cost-Effective Energy Efficiency Measures for Above Code(ASHRAE 90.1-2001 and 2007) Small Restaurant Buildings in the City of Arlington
</description>
<pubDate>Sat, 01 Oct 2011 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://hdl.handle.net/1969.1/128950</guid>
<dc:date>2011-10-01T00:00:00Z</dc:date>
</item>
</channel>
</rss>
