TAMU Homepage TAMU Libraries Homepage TAMU Digital Library Homepage

Development of a pre-screening methodology to aid in determining potential energy savings in commercial buildings

Show simple item record

dc.contributor.advisor Claridge, David E. en_US
dc.creator Hicks, Dave C. en_US
dc.date.accessioned 2011-02-22T22:23:22Z en_US
dc.date.accessioned 2011-02-22T23:43:36Z
dc.date.available 2011-02-22T22:23:22Z en_US
dc.date.available 2011-02-22T23:43:36Z
dc.date.created 2008-12 en_US
dc.date.issued 2009-05-15 en_US
dc.date.submitted December 2008 en_US
dc.identifier.uri http://hdl.handle.net/1969.1/ETD-TAMU-2400 en_US
dc.description.abstract This thesis presents a methodology developed to aid in the determination of potential sources and the potential scale of energy savings in commercial buildings. As a pre-screening tool, the methodology is designed to serve as the first analysis of the building’s potential for energy savings using limited data prior to a site visit. A Microsoft® Excel-based tool was developed to perform this analysis semi-automatically with user operation. A fundamental concept used in this methodology is that of the energy balance load, defined as heating plus electricity minus cooling. The methodology is designed to require only historical weather data, historical whole-building energy consumption data, the total conditioned floor area, and the basic function of the building. Upon following a short procedure developed and outlined in this thesis, this limited data yields information that can lead to conclusions about the building’s energy consumption. The output information includes estimates of a major building thermal parameter—the building’s overall heat transfer coefficient including the total outside air flow rate into the building. In addition to providing this information, the Excel tool includes already-formatted plots of the energy consumption commonly used in energy analysis. These include cooling, heating, and electricity vs. both outside air temperature and time. Three case studies illustrate the utility of this methodology. The calculated energy balance load—calculated using parameters determined through this methodology—yielded values on average within 5.4% of measured values. en_US
dc.format.medium electronic en_US
dc.format.mimetype application/pdf en_US
dc.language.iso en_US en_US
dc.subject energy en_US
dc.subject pre-screening en_US
dc.subject buildings en_US
dc.title Development of a pre-screening methodology to aid in determining potential energy savings in commercial buildings en_US
dc.type Book en
dc.type Thesis en
thesis.degree.department Mechanical Engineering en_US
thesis.degree.discipline Mechanical Engineering en_US
thesis.degree.grantor Texas A&M University en_US
thesis.degree.name Master of Science en_US
thesis.degree.level Masters en_US
dc.contributor.committeeMember Culp, Charles en_US
dc.contributor.committeeMember Turner, W. Dan en_US
dc.type.genre Electronic Thesis en_US
dc.type.material text en_US
dc.format.digitalOrigin born digital en_US


Files in this item

Files Size Format View
HICKS-THESIS.pdf 1.999Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record